【Origin Pic】 |
High-power UPS power supply EA900-G3 1kVA-3kVA
Power range:1kVA-3kVA
Application areas:Small and medium-sized enterprise data room, financial |
The second generation EA900 series 1-3kVA UPS is a new generation of universal UPS power supply designed and manufactured by Yishite with the latest R&D achievements and application experience. It adopts advanced DSP digital control technology to effectively improve Product performance and system reliability, and achieve higher power density integration and miniaturization. At the same time, in order to meet the personalized needs of users in all aspects, high-end low-power online UPS power products specially launched for the needs of domestic and foreign small and medium enterprises and small power supply environments can be used for user departments and servers, small local area networks, workstations, and industrial control Machines, small medical equipment, and various small precision electronic instruments provide high-reliability power protection.
1kVA-3kVA
Application field:Data room of small and medium-sized enterprises, small branches of financial system
Industrial automation control system, local area network server
Communication base station server, Internet cafe, store cashier, etc.
Adopt advanced DSP digital control technology, effectively improve product performance and system reliability, and achieve higher power density integration and miniaturization.
Active input power factor correction (PFC)
Adopting digitally controlled active power factor correction technology, so that the input power factor is as high as 0.99 or more, so as to avoid pollution to the grid environment, achieve energy saving, and reduce system investment costs.
Digital control of battery mode DC-DC converter
Using digital control, the original battery-mode DC-DC converter is changed from analog control to digital control to improve reliability.
Environmental protectionThis series of products are green and environmentally friendly products that meet the requirements of the European Union's environmental protection directive RoHS and the requirements of the national electronic information product pollution control and management standards. Under normal use of the product, it will not cause harm to humans and the environment.
Wide input voltage frequency rangeExtremely wide input voltage and frequency range, it can supply power normally even in remote areas with very harsh power environment, reducing battery discharge times and improving battery life.
Friendly man-machine interfaceRich UPS information display;
LCD display and LED status display;
Inverter functionSupport 50Hz/60Hz output or 60Hz/50Hz output frequency conversion mode to meet the special requirements of users;
50/60Hz power system adaptiveAutomatic identification, adapt to 50Hz/60Hz power system, meet the requirements of different power system
Panel setting functionThe low battery protection point (EOD) can be flexibly set to maximize battery utilization; the output voltage is set to 208V/220V/230V/240V; there are also multiple functions that can be set through the panel or background, such as ECO economic operation Mode, EPO emergency shutdown, etc., it is convenient to support a variety of personalized customization needs.
Perfect protection measuresIntegrated AC input over-voltage and under-voltage protection, output overload, short-circuit protection, inverter over-heat protection, IGBT over-current protection, battery under-voltage warning protection and battery over-charge protection and other multi-function protections in one, which greatly guarantees Stability and reliability of system operation;
With bypass function, when the output is overloaded or the UPS fails, it can go to the bypass working state without interruption, and the mains will continue to supply power to the load, and provide alarm information;
It has an alarm display function. When there is any abnormal situation, the UPS will sound and light alarm and display the current alarm information in real time, which is convenient for users to find and eliminate the abnormality;
Cold start and mains start functionUsing the battery to start the UPS directly in the abnormal situation of the mains power supply to meet the emergency needs;
When there is no mains power, the UPS can be started directly with mains power, which can be used as a high-precision stabilized power supply;
Can be used with generatorWide input voltage and frequency range, can effectively isolate the bad power generated by the generator, and provide a clean, safe and stable power supply for the load
Zero switchingDouble-conversion on-line design makes the output of UPS a pure sine wave power supply with frequency tracking, phase-locking voltage stabilization, filtering out noise, and not being interfered by power grid fluctuations, providing more comprehensive protection for the load. When the mains is unstable, the conversion time of UPS power supply mode is zero, which effectively guarantees the safety and reliability of load operation;
Intelligent battery managementAdopt intelligent battery management technology, and use the charging design with automatic equalization and floating charge switching;
It is equipped with battery overvoltage, overcharge and other protection functions to protect the battery from damage to the maximum extent;
Powerful scalability functionThe smart slot can provide a wealth of expandability functions, and you can choose SNMP card, RS485, AS400 card
★ Technical parameters of EA900 series 1-3kVA UPSModel | EA901S |
EA901H |
EA902S |
EA902H |
EA903S |
EA903H |
Rated capacity |
1kVA |
2kVA |
3kVA |
|||
Output index | ||||||
Enter the number of phases |
Single-phase three-wire (1Φ+N+PE) |
|||||
Enter the rated voltage |
208Vac/220Vac//230Vac/240Vac |
|||||
Input voltage variable range |
110-176V (50%-100% load linear derating), 176-280Vac (no derating), |
|||||
Enter the frequency variation range |
40-70Hz |
|||||
Enter the power factor |
≥0.99 |
|||||
Battery voltage |
24VDC |
48VDC |
72VDC |
|||
Number of batteries |
12V2 section |
12V4 section |
12V6 section |
|||
Output refers to | ||||||
Number of output phases |
Single-phase three-wire (1Φ+N+PE) |
|||||
Output rated voltage |
208Vac /220Vac /230Vac /240Vac |
|||||
Output voltage regulation accuracy |
±1% |
|||||
Output frequency accuracy |
Mains mode: track bypass input in synchronization state; battery mode: 50Hz/60Hz±0.1% |
|||||
Output power factor |
0.9 |
|||||
Output waveform distortion degree |
≤2% (resistive load); ≤5% (non-linear load) |
|||||
Output current crest factor |
3:1 |
|||||
Overload capability |
105%<load≤150%, transfer to bypass after 30 seconds; 125%<load≤150%, transfer to bypass after 30 seconds ; |
|||||
System indicators | ||||||
System efficiency |
Online mode: ≥90%, |
Online mode: ≥91%, |
Online mode: ≥92%, |
|||
Switching time |
0 ms |
|||||
Protection function |
Output short circuit protection, output overload protection, over temperature protection, battery low voltage protection, output over and under voltage protection, fan failure protection, etc. |
|||||
Communication interface |
Standard configuration: RS232; Optional configuration: SNMP card, RS485, USB, dry contact, temperature compensation, EPO port, etc. |
|||||
display show |
LCD+LED |
|||||
Working environment | ||||||
Operating temperature |
0~40℃ |
|||||
Storage temperature |
-25℃~55℃ (without battery) |
|||||
Relative humidity |
0%-95% (no condensation) |
|||||
Altitude |
Altitude ≤1000m, over 1000m, derating 1% for every 100m rise |
|||||
Protection level |
IP20 |
|||||
Noise Sound |
<50dB (1 meter away from the device) |
|||||
Other features | ||||||
The size of the host (W×D×H) mm |
144×336×214 |
191×418×335 |
||||
Net weight (kg) |
9.5 |
6.0 |
18.0 |
10.5 |
27.2 |
11.0 |
yan color |
black |
Remarks: 1. In the above table, "H" stands for long-acting machine (external battery), and "S" stands for standard machine (built-in battery)
2. Specifications are subject to change without notice. The pictures are provided for reference, and the actual product shall prevail.