【Origin Pic】 |
Frequency conversion UPS power supply EA600 RT series-2-3kVA
Power range:500KVA – 3000KVA
Application field: Home PC, SOHO small office environmen |
The EA600 series of products are developed by Yishite Company in response to the electrical characteristics of computer peripherals in the market. It is a sine wave online interactive UPS with energy-saving and environmental protection functions. The product uses DSP digital processing technology and has online voltage stabilization, Short circuit protection, automatic inverter frequency adjustment, output overload, battery charging management, monitoring and other functions, LCD+LED display mode, not only can intuitively understand the current operating status of the product through the LED, but also through the LCD display Various operating parameters of the product. The intelligent monitoring system can be connected to a computer via USB to monitor various operating parameters of the UPS system in real time, directly control the operation and testing of the UPS, turn on and off regularly, and can also achieve remote monitoring through SNMP cards. This series of products has high stability, high reliability, high practicability, and is an ideal power source for computers and peripheral electronic equipment.
500KVA – 3000KVA
Application field:Home PC, SOHO small office environment
Small communication switches, servers
SOHO network equipment
Commercial POS machine
Workstation and its peripheral equipment
Bank terminals, ATM systems, etc.
Advanced DSP digital processing technology, faster and more accurate data processing and control, online interactive design, high-speed online voltage stabilization technology, when the system is running normally, the system adopts an advanced BOOST charging system to supplement the battery in time , To ensure sufficient built-in battery energy, high-speed power MOS plus DSP digital processing technology, to further ensure the reliability and advancement of the product.
2) Pure sine wave technologyThis product adopts advanced SPWM modulation technology, controls high-speed power MOS, and uses isolation transformer boost technology to form a regulated and frequency-stabilized standard sine wave voltage for load use after passing through an LC filter, reducing noise interference to the load .
3) LCD+LED display modeIntuitive LED process and status display.
LCD directly displays various operating parameters of the product.
4) Ultra-wide input rangeUPS has high-efficiency online synchronous voltage stabilization technology, and the input is safe to operate from 165-280Vac, which greatly reduces the frequency of use of the UPS built-in battery and effectively extends the battery life.
5) Automatic frequency selectionWhen the UPS is connected to the mains frequency of 50Hz or 60Hz, the UPS will automatically detect the mains frequency. When the mains power is cut off, the UPS output voltage frequency will be the same as the mains frequency (50Hz or 60Hz).
6) Battery testingThe product can cooperate with the background monitoring software to periodically detect the battery status. If the UPS battery and connection line are open or the battery fails, the UPS will notify the user of the detected battery failure information via USB. At the same time, UPS will protect itself, turn off the charging system, and switch to Bypass power supply mode, adding battery temperature compensation technology, effectively extending battery life.
7) High-speed synchronous conversionThe system has the function of automatically tracking the phase of the mains to ensure that the inverter output voltage is completely in phase with the mains voltage, effectively reducing the UPS conversion time and the peak surge voltage generated during switching, ensuring that there is no Interference and no damage.
8) Humanized alarm systemIn the initial stage of battery power supply, the UPS will sound once every 5 seconds and will automatically silence the sound after about 60 seconds, which will no longer interfere with the working environment.
When the battery is about to run out, the UPS will start a rapid beeping alarm again at a frequency of 0.16 seconds to remind the staff that the battery is exhausted and the UPS is about to shut down.
When the battery is exhausted, the UPS will automatically shut down to protect the battery.
9) Unattended and intelligent monitoringThis product is equipped with an automatic switch function, which is suitable for unmanned monitoring places and remote monitoring areas. When a long-term power failure occurs, this product can also communicate with PC via USB to realize real-time monitoring, testing, and scheduled shutdown and startup. Can also pass SNMP network system Realize remote monitoring, testing and timing shutdown and startup operations.
10) Intelligent automatic shutdown technology (manual setting) monitoringThe system will automatically detect the load when the equipment is in the shutdown state and power failure. If the load is less than 3% (3~50% can be set), the UPS will judge the shutdown state for 1 minute (1~99 minutes can be set) It will automatically shut down after the battery is turned off to reduce loss and effectively extend the life of the battery.
11) Inverter no-load sleep function (manual setting)Start the inverter no-load sleep function. When the UPS is in the inverter state, the system will automatically detect the load. If the load is less than 3%, the UPS will automatically enter the sleep mode after 80s. Loading starts automatically.
★ Technical parameters of EA600 series 0.5-3kVA UPSType number | EA605H |
EA610H/EA610S/ |
EA615S/ |
EA620H/EA620S/ |
EA630H/EA630S/ |
|||
Rated capacity |
500VA/300W |
1000VA/800W |
1500VA/1200W |
2000VA/1600W |
3000VA/2400W |
|||
Enter metrics | ||||||||
Enter the number of phases |
Single-phase three-wire (L+N+PE) |
|||||||
Enter the rated voltage |
220Vac |
|||||||
Input voltage variable range |
165V~280V |
|||||||
Enter the frequency variation range |
50Hz/60Hz (automatic detection), 45-55Hz for 50Hz, 55-65Hz for 60Hz |
|||||||
Battery voltage |
12VDC |
24VDC |
36VDC(S)/48VDC(H) |
48VDC |
||||
Built-in battery capacity section number |
—— |
12V7AH×2 section |
12V9AH×2 section |
12V9AH×3 section |
12V9AH×4 section |
|||
Output indicator | ||||||||
Number of output phases |
Single-phase three-wire (L+N+PE) |
|||||||
Output rated voltage |
220Vac |
|||||||
Output voltage regulation accuracy |
Mains mode: 192-241Vac, inverter mode: 220Vac±5% |
|||||||
Output frequency accuracy |
Mains mode: track mains input frequency; inverter mode: 50Hz/60Hz±0.3Hz |
|||||||
Output power factor |
0.6 |
0.8 |
||||||
Output waveform distortion degree |
≤5% (resistive load) |
|||||||
System indicators | ||||||||
System efficiency |
Utility mode: 96% (max), inverter mode: 85% (max) < /td> | |||||||
Switching time |
≤10ms |
|||||||
Protection function |
Overload, short circuit (inverter), low battery, battery overcharge, over temperature |
|||||||
Overload time (mains mode) |
110% 120 seconds; 125% 60 seconds; 150% 10 seconds (after transfer to bypass) |
|||||||
Overload time (inverter mode) |
110% 60 seconds; 125% 10 seconds; 150% 0.7 seconds (turn off directly afterwards) < /td> | |||||||
Charging current |
Labeling machine: 1A (default), 0-5A adjustable; |
|||||||
Long machine: 10A (default); |
—— |
Long machine: 10A (default); |
Long machine: 10A (default); |
|||||
Communication interface |
Standard: USB+RJ45; Optional: SNMP |
|||||||
display show |
LCD+LED ; |
|||||||
Work environment | ||||||||
Operating temperature |
5~40℃ |
|||||||
Relative humidity |
Relative humidity ≤93% |
|||||||
Storage temperature |
-25℃~55℃ (without battery) |
|||||||
Noise Sound |
≤ 50dB (1 meter away from the device) |
|||||||
Other features | ||||||||
Net weight (Kg) |
H: 7 |
H:11.6 |
—— |
H:17.8 |
H:25.4 |
|||
S:12.2 |
S:14.2 |
S:18.5 |
S:28.1 |
|||||
RTS:14.6 |
RTS:17.2 |
RTS:21.3 |
RTS:26.7 |
|||||
Host size (W×D×H ) Mm |
H/S:144×346×215 < /td> | —— |
H:144×346.5×215 |
H/S:190×467×335 |
||||
S:144×346×215 |
S:144×411×215 |
|||||||
RTS:440×338×88 |
RTS:440×410×132 |
RTS:440×410×132 |
RTS:440×410×132 |
|||||
yan color |
black |
Remarks: 1. In the above table, "H" stands for long-acting machine (external battery), and "S" stands for standard machine (built-in battery)
2. Specifications are subject to change without notice. The pictures are provided for reference, and the actual product shall prevail.