Dongguan Shengrong Communication Engineering Co., Ltd. Shengrong

UPS INDUSTRIAL POWER ONE-STOP SOURCE MANUFACTURER WHOLESALE

4dhcpmingchen

【Origin Pic】
Medical industrial power supply EA660 250KVA
Power range:20kVA-250kVA
Application fields:Data processing center, computer room, telecommunications, finance

★ Basic introduction to online outdoor UPS

Online outdoor UPS is a company specializes in providing users with pure uninterrupted AC power equipment for outdoor communication and network equipment. It is mainly used for outdoor communication and network equipment, which are usually used in urban corners, remote suburbs, mountainous areas, etc. Designed for the power supply environment, adopting a series of designs such as high temperature resistance, severe cold resistance, salt fog resistance, corrosion resistance, dust resistance, waterproofing, lightning protection, etc., with a wide input voltage range, a wide input frequency range, and a pure, stable, and reliable output waveform. Advantages, it completely solves the interference of the harsh power supply environment on network communication equipment, power supply interruption and other phenomena, and is widely used in outdoor communication base stations in the fields of communication, radio and television, and aviation.

Power range:

20kVA-250kVA

Application field:

Data processing center, computer room, telecommunications, finance, securities, transportation, taxation, medical treatment, industrial automation

Has been certified by a third-party authority:

Tail certification, energy saving certification, seismic certification, CE certification

★ Performance characteristics

Ultra-wide input voltage and frequency range

The input voltage range is 204Vac~520Vac (half load), 277Vac~520Vac (full load), suitable for the environment with large fluctuations in the mains power grid, reducing the number of battery discharges, thereby extending the battery life;

The input frequency range is 40~70Hz, which can meet various generator equipments

Large LCD touch widescreen

Using a 5.7-inch touch screen LCD design and menu-style architecture, various UPS information can be monitored through the LCD, making all operations clear at a glance.

Modular design

Using modular design, the module capacity is 20kVA/25kVA, the UPS system is composed of 1 to 10 UPS modules, 1 to 2 charging modules, and 1 monitoring module. The user can flexibly increase the UPS according to the gradual input of the load. Number of modules. "Hot-swappable" technology is adopted between each module and the cabinet, and all modules can be hot-swapped online, realizing "zero" maintenance time.

Decentralized bypass control

Each power module has an independent bypass function inside to avoid the single-point bottleneck caused by centralized bypass.

Flexible system configuration

This series of products of our company have 100kVA, 160kVA, 250kVA conventional systems, users can flexibly configure; for future equipment expansion, as long as the user leaves a margin for the switch and cable when installing the machine for the first time, the load will increase in the future As long as you purchase UPS modules, you can expand the UPS capacity, completely avoiding the shortcomings of excessive investment in traditional UPS equipment for the first time, and truly "investing while growing", saving users valuable funds.

Flexible charging parameter settings and battery configuration

Users can set key charging parameters such as the number of battery cells, battery packs, battery capacity, charging rate, and temperature compensation coefficient through the LCD screen according to their needs. The number of battery cells in the battery pack can be arbitrarily configured within ±16/17/18/19/20. Note: The battery pack must be even in number.

Smart battery management

The independent intelligent charging module automatically performs three-stage intelligent charging management for the battery pack. The first stage of high current constant current charging can quickly recharge about 90% of the power; the second stage of high and low voltage cycle charging can homogenize the battery voltage and fully charge the battery; the third stage of floating charge maintains to ensure that the power is not lost. At the same time, the charging module also has functions such as battery reverse connection protection, battery overcharge protection, output short circuit protection, battery not connected prompt, and charging voltage temperature compensation.

Standard configuration input, output, maintenance bypass switch

Standard configuration input, output, maintenance bypass switches, easy to install and operate, while reducing the cost and floor space of users purchasing power distribution cabinets.

Standard C-level lightning protection module

It has surge protection functions such as lightning protection, which can effectively prevent lightning strikes from damaging the equipment.

Super protective treatment

The air inlet of the machine adopts the imported dust-proof net design, and the internal PCB board adopts the three-proof treatment, moisture-proof, mould-proof and smoke-proof to ensure that it is suitable for various harsh environments.

Rich communication interface functions

Standard configuration USB, RS232, RS485, dry contact, optional SNMP card, to meet the various communication needs of users.

★ General options description

Function

Function description

Standard

Optional

SAP coding

Communication interface

RS232, USB

 

 

Communication interface

RS485

 

 

Communication interface

Dry contact card (inverter output, mains abnormality, output overload, bypass output, system failure, low battery voltage alarm, system alarm )

 

 

Network monitoring card

SNMP card: built-in card

 

90-005391-00 does not support SMS modem

90-010891-00 support SMS modem

SMS alerter

Match SNMP card 100P/100E, support SIM standard card, frequency band: GSM850/900/1800/1900MHz

 

90-005396-00

EPO.

Emergency shutdown

 

 

Battery cold start assembly

When there is no utility power, it can be powered on by battery inverter

 

 

Parallel components

Realize the parallel function between single machines

 

90-004844-00 (When placing an order, please note that the dosage for a single cabinet is 1, that is, the dosage for two parallel machines is 2)

Power distribution module Standard 1P32A*15 ABB

 

90-004840-00 (supporting EA66100 system cabinet)
90-014379-00 (supporting EA66160 system cabinet)
EA66250 system cabinet has no power distribution

Battery module ±20 9AH batteries (occupies two slots)

 

90-006226-00

Battery temperature
Sampling module

RJ45 lead-out port (10K thermistor), charging voltage temperature compensation

 

90-005404-00 


★ Package size and weight

Name

Model

Machine size W*D*H(mm)

Package size W*D*H(mm)

Net weight (Kg)

Gross weight (Kg)

color

EA660 series

EA66100

600*1000*1600

700*1100*1780

225

233

black

EA66160

600*1000*2000

700*1100*2180

290

298

EA66250

600*1000*2000

700*1100*2180

280

288

Power Module

482*590*131

835*665*245

28

31

Charging module

27

30

Monitoring module

7

10


★ Product power range and ERP code

Standard

ERP coding

Specifications

Power

Battery voltage

The entire cabinet

90-004787-00

EA66100KVA system cabinet (with dual inputs)

Configure up to 4 power modules, maximum output power: 100kVA/90kW

±190-±240 can be set

90-004797-00

EA66160KVA system cabinet (with dual input)

160kVA system cabinet, up to 8 power modules (up to 6 25k power modules can be configured) Maximum output power: 160kVA/160kW < /p>

±190-±240 can be set

90-004826-00

EA66250KVA system cabinet (with dual inputs)

Configure up to 10 power modules, maximum output power: 250kVA/225kW

±190-±240 can be set

Power Module

90-014702-00

EA660III-20kVA power supply power module (dual input, power factor 1)

20kVA/20kW

±190-±240 can be set

90-014703-00

EA660III-25kVA power supply power module (dual input, power factor 0.9)

25 kVA /22.5kW

±190-±240 can be set

90-004814-00

EA66III monitoring module (dual input, English neutral)

(Standard configuration in the whole cabinet)

 

90-004818-00

EA660III charging module

30A charging module (standard configuration in the whole cabinet)

±190-±240 can be set